Thermocouple Replacement
We replace the thermocouple with an OEM part matched to your Rheem, AO Smith, or Bradford White tank. Includes millivoltage testing before and after, ferrule tightening with a wrench, and a 60-second pilot hold test.
Every Pilot Light & Thermocouple Repair Keller TX visit includes a full pilot circuit diagnosis, not just a parts swap. Here is what is covered in the standard price and what we quote separately if we find it.
We replace the thermocouple with an OEM part matched to your Rheem, AO Smith, or Bradford White tank. Includes millivoltage testing before and after, ferrule tightening with a wrench, and a 60-second pilot hold test.
Sediment and dust clog the pilot tube and orifice, causing a weak flame that cannot heat the thermocouple. We pull the tube, blow it out with compressed air, and clean the orifice with a torch tip cleaner.
We test the gas valve with a manometer and confirm it holds pressure when the pilot is lit. If the valve is failing, we quote replacement separately. No guessing, no parts swapping.
Every gas connection we touch gets a soap-solution leak test. We also inspect the flue, combustion air openings, and pressure relief valve while we are in the burner compartment. Ten minutes, included.
We fire the main burner, watch the flame pattern for two to three minutes, and confirm the thermostat is calling correctly. Then we show you the pilot sight glass and explain what to watch for.
Pilot Light & Thermocouple Repair Keller TX is a gas water heater service that restores the standing pilot flame and replaces the thermocouple when it stops generating enough millivoltage to hold the gas valve open. The thermocouple is a small copper-and-steel probe sitting in the pilot flame. It produces roughly 20 to 30 millivolts, and that tiny current is what tells the gas valve it is safe to stay open. When the probe corrodes or the pilot orifice clogs with dust, the flame dies within seconds of you releasing the reset button.
In Keller, most pilot failures we see are thermocouple drift, not a bad gas valve. Homes in Hidden Lakes and Marshall Ridge with 8-to-12-year-old tanks are the usual call. You press the pilot button, the flame lights, you let go, and it goes out. Sometimes you smell gas and shut everything down. We test the thermocouple with a multimeter, check the pilot tube for sediment, and verify the gas pressure at the valve. If the tank is also leaking or the anode rod is gone, we tell you straight.
Every Pilot Light & Thermocouple Repair Keller TX visit follows the same five steps. You will know what we are doing and why before we start.
Schedule
Call or book online — a real human picks up and confirms a 2-hour arrival window.
Diagnose
Licensed tech inspects on-site, then walks you through the cause and your options.
Fix
The job is completed to code and done right the first time — no shortcuts, no surprises.
Guarantee
Every job backed by a written workmanship warranty — and we stand behind it.
Multimeter
Reads thermocouple millivoltage while the pilot is lit. A reading below 15 millivolts means replacement. We test before and after the swap.
Manometer
Measures gas pressure at the valve to confirm the supply is within the manufacturer's spec. Rules out gas supply issues before we replace parts.
Torch Tip Cleaner
Clears the pilot orifice without enlarging it. A clogged orifice is a common cause of a weak flame that cannot heat the thermocouple.
Wrench and Screwdriver Set
Tightens thermocouple ferrules and opens the burner compartment. We use the right size to avoid stripping brass fittings.
Pipe Cutter and Soldering Iron
For gas line repairs and pilot tube replacement when the existing tube is kinked or corroded. Copper pipe only, code-correct.
Soap Solution and Leak Detector
Tests every gas connection we touch. We do not relight until the joint passes.
Millivoltage Testing
We disconnect the thermocouple from the gas valve and read the open-circuit millivoltage with the pilot lit. The manufacturer's spec is usually 20 to 30 millivolts. Anything below 15 gets replaced. This is the difference between a guess and a diagnosis.
Pilot Tube Cleaning
We pull the pilot tube, blow it out with compressed air, and clean the orifice with a torch tip cleaner. Sediment and dust are common in Keller tanks that have never been flushed. A clean tube gives a steady blue flame that wraps the thermocouple.
Gas Valve Pressure Test
We connect a manometer to the gas valve inlet and confirm the supply pressure is within spec. If the valve will not hold pressure when the pilot is lit, we quote replacement. This rules out a bad valve before we sell you a thermocouple.
Code-Correct Venting Check
We inspect the flue and combustion air openings against Tarrant County gas code. A blocked flue can pull the pilot flame away from the thermocouple. If the vent is wrong, we tell you and quote the fix.
01
What we do: We treat no-hot-water calls as priority. Call before 2 p.m. and we usually have a same-day slot. The technician tests the thermocouple, replaces it if needed, and confirms the burner fires before leaving.
→ Hot water back the same afternoon, usually within 90 minutes of arrival.
02
What we do: Leave the house and call us from outside. We walk you through shutting the gas off at the tank. Then we dispatch a technician to leak-test every connection and find the source.
→ The leak is found and fixed, and the system passes a soap-solution test before we relight.
03
What we do: Intermittent pilot failures usually mean a thermocouple on the edge of spec or a pilot tube that is partially clogged. We test millivoltage, clean the tube, and replace the thermocouple if it is marginal.
→ A stable pilot flame that holds through the heating season, not just for a week.
04
What we do: We diagnose the pilot circuit and check the tank for rust, sediment, and anode rod condition. If the tank is near end of life, we quote replacement alongside the repair so you can compare.
→ You get honest numbers on both paths and decide whether to repair or replace.
Keller sits in Tarrant County, and our gas water heaters work hard here. Summers push tank temperatures up, and the pilot assembly sits in a hot burner compartment for months. That heat ages the thermocouple faster than in cooler climates. Winters are mild but we still get freeze events, and a pilot that is already weak can drop out when the incoming water temperature falls. Most of the tanks we see are Rheem, AO Smith, and Bradford White units installed in the 2010s. Homes in Hidden Lakes and Marshall Ridge often have tanks in the garage, which means dust and attic debris find their way into the pilot tube. If you are searching for water heater pilot light repair near me Keller, we are already working in your ZIP. We cover 76248 and 76262 daily and follow Tarrant County gas code on every connection.
Hidden Lakes
Many homes here have garage-mounted gas tanks with 10-to-15-year-old thermocouples. Dust from the garage clogs pilot tubes, so we clean the orifice on every call.
Marshall Ridge
Newer construction with AO Smith and Rheem tanks. We see thermocouple drift around the 8-year mark, often with a pilot that lights but will not hold.
Old Town Keller
Older housing stock with Bradford White and discontinued tanks. We carry universal thermocouple kits that meet the same millivoltage spec.
Overton Ridge
Tanks in closets and utility rooms with tight access. We bring a compact wrench set and a drop light to work in confined spaces without cutting drywall.
Hot summers and garage-mounted tanks
Burner compartments run hot from June through September, which shortens thermocouple life. We see more pilot failures in late summer than any other season.
Hard water and sediment buildup
Keller water leaves mineral scale in the tank. Sediment flakes can clog the pilot orifice and cause a weak flame. Annual flushing prevents most of these calls.
Winter freeze events
When incoming water drops near freezing, a marginal thermocouple can fail. We test millivoltage hot and cold to catch thermocouples that only fail under load.
Tarrant County gas code
Venting and combustion air requirements are enforced on every install and repair. We check the flue on every pilot call and flag code issues before they become a safety problem.
A dead pilot light shows up in a few predictable ways. Here are the ones we see most in Keller, TX and what we do about them.
Problem
You hold the button, the flame catches, you release, and it dies. That usually means the thermocouple is not generating enough millivolts to hold the gas valve open.
Our Fix
We test the thermocouple with a multimeter. If it reads below 15 millivolts, we replace it with an OEM part and clean the pilot tube while we are in there. Most jobs are done in under 90 minutes.
Problem
You press the button and hear no click, see no spark, or smell gas. This can be a clogged orifice, a bad igniter, or a gas supply issue.
Our Fix
We check gas pressure at the valve, inspect the pilot orifice, and test the ignition system. If the gas valve is stuck closed, we quote replacement. If it is a supply issue, we tell you to call your gas provider.
Problem
The flame lights and holds for a while, then drops. This often points to a thermocouple that works cold but fails hot, or a draft pulling the flame away.
Our Fix
We test the thermocouple hot and cold, check the flue for blockages, and inspect the combustion air openings. A new thermocouple and a flue check usually solve it. We also verify the vent is code-correct.
Problem
Rust and sediment fall from the flue and clog the pilot assembly. This is common on tanks over 10 years old and often comes with a failing anode rod.
Our Fix
We vacuum the burner compartment, clean the pilot tube, and inspect the anode rod. If the rod is gone, we replace it. If the tank is rusting from the inside, we tell you straight about replacement.
A dead pilot light means cold showers and a tank that will not heat. Here is what you get when you book Pilot Light & Thermocouple Repair Keller TX with us.
Same-Day Hot Water
Most pilot and thermocouple jobs are done in 60 to 90 minutes. We stock Rheem, AO Smith, and Bradford White thermocouples on every truck, so we rarely need a second trip. You get your hot water back the same day you call, not three days later.
Straight Answers on Cost
Thermocouple replacement cost Keller TX runs $180 to $320 for a standard gas tank, parts and labor included. If the gas valve is also bad, we quote that separately before we touch it. No surprise line items, no pressure to replace a tank that still has life left.
Licensed Gas Work Only
Pilot assemblies, thermocouples, and gas valves are not DIY territory. Our technicians hold a State plumbing license and follow Tarrant County gas code on every connection. We leak-test with a manometer and soap solution before we button the burner compartment back up.
Emergency Pilot Light Repair Keller TX Same-Day
No hot water before a holiday or a house full of guests is an emergency. We run 24/7 dispatch for Keller, TX and keep after-hours slots open for gas pilot failures. Call (817) 839-0768 and we will tell you the soonest we can be there.
Google ★★★★★4.9
Pilot light went out on our Rheem tank and they had it fixed the same day. The tech tested the thermocouple with a multimeter and showed me the reading. $240 total. Honest work, no upsell.
Yelp ★★★★★4.8
Called at 8 a.m. about no hot water, had a technician at the house by 11. He replaced the thermocouple and cleaned the pilot tube. Explained everything. Fair price for Keller.
BBB ★★★★★4.9
We had two other plumbers fail to fix an intermittent pilot. Keller Water Heater Pros found a blocked flue and fixed it in one visit. Should have called them first.
Google ★★★★★5.0
Same-day service on a Saturday. The technician was licensed, wore boot covers, and left the utility room cleaner than he found it. Pilot has been solid for three months.
Our technicians work on gas water heaters every day in Keller and across Tarrant County. We carry OEM thermocouples for Rheem, AO Smith, Bradford White, and Bosch, plus universal kits for older tanks. Every tech is trained on standing-pilot and electronic ignition systems, and we follow the manufacturer's millivoltage spec rather than guessing. We are a state-licensed plumbing contractor, EPA certified, and NATE certified on gas appliance diagnostics. When we open a burner compartment, we know what a healthy pilot flame should look like: blue, steady, and wrapping the thermocouple tip.
Real answers to the questions we hear most often from local homeowners and property managers.
If your tank is 12 years or older and the thermocouple has failed twice, replacement often costs less than another repair. We install Rheem, AO Smith, and Bradford White tanks with code-correct venting and expansion tanks. Keller permits handled.
View Water Heater Installation & ReplacementTankless units use electronic ignition, not a standing pilot, but they still fail to fire. We diagnose igniter, flame sensor, and gas valve faults on Bosch and Rheem tankless models. Same-day service across Keller and Tarrant County.
View Tankless Water Heater RepairPilot and thermocouple work is one part of gas water heater repair. We also fix gas valves, thermostats, and burners. If your tank rumbles, smells, or will not heat, we diagnose the whole system, not just the pilot.
View Gas Water Heater RepairElectric tanks do not have a pilot light, but they fail the same way: no hot water. We test heating elements, thermostats, and dip tubes with a multimeter. If you have an electric tank in Keller, TX, call us for a same-day diagnosis.
View Electric Water Heater RepairA leaking water heater and a dead pilot often show up together. We find the source, whether it is a fitting, a pressure relief valve, or a cracked tank. If the tank itself is leaking, we quote replacement before you spend money on a repair.
View Water Heater Leak RepairWhen a tank bursts, you need it out and a new one in the same day. We stock replacement tanks and handle the haul-away, permit, and code inspection. Emergency dispatch available 24/7 for Keller and surrounding neighborhoods.
View Burst Water Heater ReplacementWe're here to help! Reach out to us for any questions or to schedule a service. We typically respond within the hour.
Phone
(817) 839-0768Address
Keller, Texas
Hours
Mon–Fri: 7AM – 7PM
Sat: 8AM – 4PM
Sun: Emergency Only
24/7 Emergency Available